FLT3-ITD and NPM1 by PCR
CD135, Fms-like tyrosine kinase 3 (FLT-3), Internal tandem duplication, NPM1 insertion
- Tech Only CPT
- Tech Pro CPT 81245, 81310
- PowerPath Code FLT3ITDNPM1
- Schedule Monday - Friday (Variable)
- Turn Around Time 2-4 Days
- Disease State Acute Myeloid Leukemia (AML) / Myeloid Sarcoma
- Methodology PCR, PCR restriction enzyme digestion, PCR-based fragmentation analysis
Organs
Specimen Requirements
Minimum of 1 mL whole blood in a purple (EDTA) or pink top tube (EDTA); minimum of 1 mL of bone marrow aspirate in a purple, pink, or green (heparin) top tube.
Clinical Significance
FLT3 is a receptor tyrosine kinase that is expressed on early hematopoietic progenitor cells and plays an important role in stem cell survival and differentiation. Internal tandem duplication mutations arise from duplications of the juxtamembrane portion of the gene and result in constitutive activation of the FLT3 protein. This mutation has been identified in ~20-30% of patients with acute myelogenous leukemia (AML) and appears to be associated with a worse prognosis.
The Nucleophosmin (NPM1) gene is one of commonly mutated genes in acute myeloid leukemia (AML), occurring in about 35% of AML patients at diagnosis and 60% of adult cytogenetically normal AML (CN-AML). The vast majority of NPM1 mutations are insertions in the last exon occurring near the C-terminus of the protein resulting in cytoplasmic localization. NPM1 insertion mutations, in conjunction with a normal karyotype and the absence of the FLT3 mutation, are associated with a good response to induction chemotherapy.
Required Patient Info
Copy of the referring client's requisition form to accompany specimen.
Storage and Transportation
Refrigerated: 5 days; ambient (room temperature): 3 days; specimen must be received by laboratory within 7 days of collection.
Cause for Rejection
Frozen specimen; clotted or grossly hemolyzed specimens; serum; specimens without 2 patient identifiers; serum or plasma, aliquots (previously open containers); specimens that were received >7 days after collection.
Retention
Whole blood and bone marrow - 1 week.
Comments
This test was developed and its performance characteristics determined by CellNetix Labs LLC. The U.S. Food and Drug Administration (FDA) has not approved or cleared this test. However, FDA approval or clearance is currently not required for clinical use of this test. The results are not intended to be used as the sole means for clinical diagnosis or patient management decisions. CellNetix is authorized under Clinical Laboratory Improvement Amendments (CLIA) to perform high-complexity testing.
LOINC Code(s)
79210-1; 85100-6; 54448-6; 75034-9